b0Daikin b0 · DM97MC/DC97MC modulating gas furnace display
Daikin’s DM97MC/DC97MC furnace manual lists this as: The blower motor is not running.
Daikin · DM97MC/DC97MC modulating gas furnace · 24 code records
Search the exact display or flash pattern. These Daikin furnace codes come from the linked manual and apply only to its named models; they are not repair instructions.
These furnace records come from three official manufacturer manuals and remain tied to their named equipment families: Daikin DM97MC/DC97MC, Trane *UH1/*DH1, and Goodman 80% single-stage furnaces. They are not a general HVAC code list, and technician-facing displays are not homeowner repair instructions. The article scope may not cover every Daikin DM97MC/DC97MC modulating gas furnace model or revision.
What this list covers
This page collects 24 source-linked displays for the Daikin DM97MC/DC97MC modulating gas furnace family. All 24 records on this page come from one daikincomfort.com document, “Daikin · Official DM97MC/DC97MC installation manual”. That source was last checked on September 28, 2026.
19 of the 24 displays are letter-and-number displays such as b0, and 5 are letter-only displays such as EA. Copy the display character for character before comparing it with a card. Every card restates the manual's description of the display; none of them is a repair instruction.
There is no exact model crosswalk here. A code on this page is tied to the DM97MC/DC97MC modulating gas furnace family named in the Daikin source, not to a specific model number or control revision.
Scoped to the DM97MC and DC97MC modulating gas furnaces named in Daikin’s August 2024 manual. These are technician-facing troubleshooting or status descriptions, not homeowner repair steps; do not open the cabinet, test gas or electrical components, or reset safety devices. Use a qualified HVAC professional.
b0Daikin’s DM97MC/DC97MC furnace manual lists this as: The blower motor is not running.
b1Daikin’s DM97MC/DC97MC furnace manual lists this as: The blower motor has a communication error.
b2Daikin’s DM97MC/DC97MC furnace manual lists this as: The blower motor horsepower configuration does not match.
b3Daikin’s DM97MC/DC97MC furnace manual lists this as: The blower motor is operating at a power, temperature, or speed limit.
b4Daikin’s DM97MC/DC97MC furnace manual lists this as: The blower motor reports a current trip or lost-rotor condition.
b5Daikin’s DM97MC/DC97MC furnace manual lists this as: The blower motor reports a locked-rotor condition.
b6Daikin’s DM97MC/DC97MC furnace manual lists this as: The blower motor reports an overvoltage, undervoltage, or overtemperature trip.
b7Daikin’s DM97MC/DC97MC furnace manual lists this as: The blower motor has incomplete operating parameters.
b9Daikin’s DM97MC/DC97MC furnace manual lists this as: The furnace reports low indoor airflow.
E0Daikin’s DM97MC/DC97MC furnace manual lists this as: Lockout after repeated ignition retries or flame recycles.
E1Daikin’s DM97MC/DC97MC furnace manual lists this as: The low-stage pressure-switch circuit is closed when it should be open at the start of heating.
E2Daikin’s DM97MC/DC97MC furnace manual lists this as: The low-stage pressure-switch circuit is open when the control expects it to close.
E3Daikin’s DM97MC/DC97MC furnace manual lists this as: The high-limit switch is open.
E4Daikin’s DM97MC/DC97MC furnace manual lists this as: Flame is detected when the control expects no flame.
E5Daikin’s DM97MC/DC97MC furnace manual lists this as: The furnace reports an open fuse.
E6Daikin’s DM97MC/DC97MC furnace manual lists this as: The flame-sense signal is below the expected level.
E7Daikin’s DM97MC/DC97MC furnace manual lists this as: The manual lists an igniter fault or improper grounding.
E8Daikin’s DM97MC/DC97MC furnace manual lists this as: The high-stage pressure-switch circuit is closed when it should be open at the start of heating.
E9Daikin’s DM97MC/DC97MC furnace manual lists this as: The high-stage pressure-switch circuit is open when the control expects it to close.
EADaikin’s DM97MC/DC97MC furnace manual lists this as: The manual lists reversed 115 VAC polarity.
ECDaikin’s DM97MC/DC97MC furnace manual lists this as: The inducer motor reports an overcurrent fault.
EdDaikin’s DM97MC/DC97MC furnace manual lists this as: The rollout-switch circuit is open.
EFDaikin’s DM97MC/DC97MC furnace manual lists this as: The auxiliary input is open.
IFDaikin’s DM97MC/DC97MC furnace manual lists this as: The integrated control module reports an internal fault.
No matching code in this manufacturer article set. Check the exact display on the official support site.
Before you act
HVAC & furnaces: These are technician-facing gas-furnace references, not repair guides. Do not open the furnace, test wiring or gas components, adjust combustion settings, or reset safety devices. Use a qualified HVAC professional; if you smell gas, leave the area and contact your gas utility or emergency services from a safe location.
These summaries describe the manufacturer's published explanation. They are not a remote diagnosis and do not establish that a specific component has failed.
Confirm the exact unit
This directory does not hold a Daikin-published label location for the DM97MC/DC97MC modulating gas furnace. The installation manual cited on each card identifies the models it covers; read the rating plate only where it is visible without opening the cabinet.
Cited documents · 1 distinct source
A check date records when the source was last reviewed for this directory. It is not a publication date or proof that the source covers every model.