HVAC Diagnostics · Optical Pulse Simulator

Furnace Blinking Light &
Flash Code Decoder

Identify Carrier, Goodman, Lennox, Trane, and York blinking LED status patterns. Watch the virtual LED pulse simulator, match blink tempo, and review conservative stop conditions. Codes are compiled from manufacturer documentation and vary by control board, so confirm against the label inside your unit's door or the owner manual.

Diagnostic optical decoder

Decode LED blink patterns through the inspection viewport.

Modern residential gas furnaces communicate operational status and safety lockouts through flashing red, amber, or green LEDs on the integrated furnace control board. Observe the light through the viewing window if your furnace has one (do not remove access panels), then select your brand or tap the tempo below. Each entry names the manufacturer document it was checked against. Entries with a source note were corrected or added on October 11, 2026 to match that document.

Step 1: Select Brand & Observed Pattern

Step 2 (Optional): Tap Blink Tempo

Tap the button in rhythm with your furnace light to measure cadence and auto-detect patterns.

Taps0
Tempo--

Observe the blinking LED through the glass and tap with each flash...

Virtual LED Simulator

Simulated optical timing & pulse cadence

IFC Board Diagnostic Window
STATUS LED
Simulating: 3 pulses · 1.5s Pause · Repeating

Tip: Carrier status codes are two digits: short flashes give the first digit and long flashes the second (3 short + 1 long = code 31). Some Lennox boards report codes with two LEDs. The Goodman, Trane, and York boards listed here use repeating flash counts.

Carrier Gas Furnace Diagnostics

Code 31

🟡 TIER 2: CAUTION & SERVICE RECOMMENDED
Safety Classification:

Venting & Draft Fault: Inducer pressure switch did not detect adequate venting vacuum.

Documented Meaning:

High-heat pressure switch or relay did not close or reopened (58CVA/58CVX two-stage wording). The guide says the control relay may be defective or the gas valve mis-wired, and refers to code 32, whose checks include restricted vent, excessive wind, and inadequate combustion air supply.

Observed Furnace Symptom:

Inducer motor runs but burners never ignite, or burners shut off shortly after lighting.

Safe Homeowner Inspection Steps:
  • Inspect the PVC exhaust and intake vent pipes outside your home to ensure they are free of snow, ice, or nests.
  • Inspect the condensate drain tubing visible outside the cabinet for kinks, freezing, or water backups.
  • Verify that the furnace filter is seated properly and not causing extreme static pressure.
Stop Conditions & Mandatory Service Thresholds:
  • Do not disconnect or blow directly into pressure switch silicone hoses.
  • Do not operate the furnace if vent pipes are disconnected, damaged, or leaking combustion exhaust indoors.
  • If vents are clear outside, shut down the furnace and contact a licensed HVAC professional to inspect the inducer assembly.
Codes vary by control board

Reference charts

Furnace Flash Code Reference by Manufacturer

Flash patterns compiled from manufacturer documentation, with the source for each entry. Entries with a source note were corrected or added on October 11, 2026 to match the cited document. Codes vary by control board: confirm against the label inside your unit's door or the owner manual before acting.

Carrier Furnaces

9 Codes

Goodman Furnaces

9 Codes

Lennox Furnaces

4 Codes

Trane Furnaces

8 Codes

York Furnaces

11 Codes

Frequently Asked Questions

What does 3 red flashes mean on a Goodman furnace?

On the Goodman GMS8/GDS8/GHS8 wiring-diagram chart, 3 flashes means "Pressure switch stuck open." Goodman's RS6621301 service manual lists possible causes for a pressure switch circuit that is not closed, including a blocked, pinched, or improperly connected pressure switch hose, a blocked flue, or a weak induced draft blower. From outside the furnace, an owner can check that exterior vent terminations are not blocked by snow, ice, or debris and that visible condensate drain lines are not kinked. Leave pressure switch, hose, and inducer checks to a qualified HVAC technician. Goodman control boards differ, so confirm the code against the chart for your furnace.

Why is my Carrier furnace blinking code 31?

Carrier status codes are two digits: the first digit is the number of short flashes and the second is the number of long flashes, so code 31 is 3 short flashes followed by 1 long flash. Carrier's 58CVA/58CVX troubleshooting guide (TG-GFC80-02) defines code 31 as "high-heat pressure switch or relay did not close or reopened" and refers to code 32, whose checks include a restricted vent, excessive wind, and inadequate combustion air supply. Meanings vary by Carrier model, so confirm against the status-code label for your furnace. From outside the cabinet, an owner can check that exterior vent terminations are not blocked by snow, ice, or debris; leave pressure switch and inducer checks to a qualified technician.

How do I count furnace blinking lights accurately?

If your furnace has a viewing window, watch the status LED through it without removing any panels. Note the color (red, amber, or green), count the flashes until the longer pause, and watch two or three repeats to make sure you counted the same number each time. On Carrier boards, also note which flashes are short and which are long. Then compare your count with the chart for your exact furnace; codes differ between control boards.

What does a rapid blinking furnace light mean?

It depends on the board. On the Carrier 58CVA/58CVX and Goodman GMS8 boards we checked, rapid flashing means line-voltage polarity is reversed (Goodman's chart adds "verify ground"). On York UTEC boards, a rapid red flash means incorrect 24 VAC phasing or a twinning error, and a rapid amber flash means low flame sense current. Lennox's G50DF board signals reversed polarity with LED #1 flashing fast and LED #2 flashing slowly. Turn the furnace off and have a licensed electrician or HVAC technician check wiring, polarity, and grounding.

Can I reset a furnace by turning the power switch off and on?

Some manuals describe a specific lockout reset. For example, Trane's *UH1/*DH1 installer's guide says a lockout must be manually reset by turning system power off, on, off, and on again within 30 seconds, and Carrier's 58CVA/58CVX guide says its ignition and limit-circuit lockouts auto-reset after 3 hours. A reset does not fix the cause. If the code returns, leave the furnace off and call a qualified technician. Never bypass safety switches, and do not repeatedly reset a furnace showing a rollout, flame-sense, or gas valve fault.

Safety disclaimer: This furnace light decoder is an informational reference compiled from the manufacturer documents cited on each entry. Those documents cover specific model families, and flash codes differ between control boards, so the chart for your own furnace takes precedence. Safety tiers are ErrorCodeDecoder editorial triage, not manufacturer guidance. This is not on-site diagnosis or repair instruction. If you smell gas, do not touch electrical switches; leave and call your gas supplier or 911 from outside. If a carbon monoxide alarm sounds or anyone feels unwell, get to fresh air and call 911.

Documents reviewed (October 11, 2026):Carrier TG-GFC80-02 Troubleshooting Guide (58CVA/58CVX), status codes pp. 6–8; Carrier 59MN7A-01T Troubleshooting Guide (59MN7A), status codes pp. 8–9; Goodman SS-GMS8 specification sheet (GMS8/GDS8/GHS8, 9/15), wiring-diagram LED chart p. 11; Goodman RS6621301 Service and Troubleshooting manual (80% single-stage GR9S80/GD9S80 family, Nov. 2023), pp. 20 and 34; Lennox G50DF Installation & Maintenance (505,255M, 10/09), SureLight diagnostic codes p. 32; Trane 18-CD29D1-14-EN Installer's Guide (*UH1/*DH1), Table 21 p. 39; York ST-045-09 Service Tips: UTEC control boards on single- and two-stage furnaces (Sept. 2009), p. 5.